Lcms
Closed Combined synopsis/solicitation (open for bids)
This opportunity is closed. It is kept here for reference. Similar opportunities that are open now are listed below.
Response deadline: Fri, Jan 30, 2026, 11:00 AM EST
About this opportunity
Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states.Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.
How to respond
Responses are submitted to the government, not through WhatGovBuys. Read the full notice and every attachment on SAM.gov, including amendments, before you prepare an offer. You need an active SAM.gov registration to receive a federal award.
Open opportunities like this one
NCSS - Coldhead Exchange Parts and Calibration for
- Status
- Open for bids
- Agency
- National Institutes of Health
- Deadline
- Responses due Nov 30, 2026 (1 day left)
Sensigent MSEM 160
- Status
- Open for bids
- Agency
- Department of the Army
- Deadline
- Responses due Nov 30, 2026 (2 days left)
- Set-aside
- Small Business Set Aside - Total
Region 8 Laboratory - SampleSense base modules and
- Status
- Open for bids
- Agency
- Environmental Protection Agency
- Deadline
- Responses due Nov 30, 2026 (2 days left)
- Set-aside
- Small Business Set Aside - Total
- Place of performance
- Denver, CO
Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.
- Status
- Open for bids
- Agency
- Department of the Army
- Deadline
- Responses due Dec 1, 2026 (3 days left)
- Set-aside
- No Set aside used
- Place of performance
- Gunpowder, MD
66--Camera,infrared,indust
- Status
- Open for bids
- Agency
- Defense Logistics Agency
- Deadline
- Responses due Dec 2, 2026 (3 days left)